0 920i serial commands, 920i serial commands – Rice Lake Digital/Diagnostic - iQube User Manual

Page 45

Advertising
background image

42

iQUBE

Installation Manual

8.0

920i Serial Commands

The following section lists

920i

serial commands used to configure and control the

iQUBE

. See the

920i

Installation Manual, PN 67887, for more information about using serial commands.

Command

Description

Values

SJ.SERIAL_NUMBER#n

iQUBE

serial number

Read-only output

SJ.CONFIG#n

iQUBE

primary-secondary

configuration

8/0/0/0, 4/0/0/0, 4/8/0/0, 4/4/0/0, 4/4/4/0, 4/4/4/4, 8/4/0/0, 8/4/
4/0, 8/8/0/0

SJ.SECT_TYPE#n

Section type

PAIRED, CIRCULAR

SJ.VERSION.s#n

System version

Read-only output.
s
is the system number, n is the

920i

serial port number.

SJ.DUMP#n

Dump diagnostic parameters

Read-only output.
Dumps all SJ parameters for the

iQUBE

connected to port n.

SJ.DOWNLOAD#n

Download to

iQUBE

Downloads configuration and resets

iQUBE

n is the.

920i

serial port number to which the

iQUBE

is connected.

Table 8-1.

920i iQUBE Serial Commands

Command

Description

Values

SJ.LC.ID.c#n

Load cell ID

Load Cell A1, load_cell_ID (24 characters, maximum)

SJ.LC.SRLNUM.c#n

Load cell serial number

(16 characters, maximum)

SJ.LC.CAPCTY.c#n

Load cell capacity

1–500000

SJ.LC.SENS.c#n

Load cell sensitivity

0.0001–9.9999 (mV/V)

SJ.LC.TRIM.c#n

Load cell trim factor

0.0001–9.9999

SJ.LC.ZERO.c#n

Load cell zero value

–0.5 to 45.0

For load cell (SJ.LC.) commands ending with “c#n”, c is the load cell number, n is the

920i

serial port number.

Table 8-2.

920i iQUBE Load Cell Serial Commands

Command

Description

Values

SJ.PLAT.NAME.p#n

Platform name

Platform1, platform_name (24 characters, maximum)

SJ.PLAT.CELLS.p#n

Platform load cells

0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0 (specify comma-separated list
of load cell numbers associated with this platform) or
NONE
(to clear load cell list)

SJ.PLAT.SIM.p#n

Platform simulated cell

0, 1–16

SJ.PLAT.WVAL.p#n

Platform test weight value

0.0–9999999.0

SJ.PLAT.WSPAN.p#n

Platform span calibration

–0.5 to 512.0

SJ.PLAT.WLIN.V1.p#n
SJ.PLAT.WLIN.V5.p#n

Platform test weight value for
linearization points 1–5

0.0–9999999.0

SJ.PLAT.WLIN.F1.p#n
SJ.PLAT.WLIN.F5.p#n

Actual raw count value for platform
linearization points 1–5

–0.5 to 512.0

SJ.PLAT.CALTYPE.p#n

Platform calibration type

NONE, FACTORY, CALMATCH, SECMATCH

SJ.PLAT.CALMULT.p#n

Retrieve platform calibration data

For platform (SJ.PLAT.) commands ending with “p#n”, p is the platform number, n is the

920i

serial port number.

Table 8-3.

920i iQUBE Platform Serial Commands

Advertising