3 configuration and calibration summary – Rice Lake Digital/Diagnostic - iQube User Manual

Page 24

Advertising
background image

920i Indicator Configuration

21

SYSTEM: The system setup display is divided into three areas:

System (middle section): Highlight the system being configured, then use the

left

arrow key to move to

the Available Platform section.

Available Platforms (left section): Use this section to assign platforms to the system. Use the

up

and

down

keys to highlight the desired platform, then press the

Add

softkey to assign the platform to the

system.

Associated Platforms (right section): Lists platforms that have been assigned the system. A system
diagram is displayed in the center of the screen.

Press

Done

to return to the configuration menu.

2. Press the

Download

softkey. Use the

up

and

down

keys to select

Download iQUBE configuration only

, then

press

enter

.

3. Cycle power on the

iQUBE

to initialize the changed configuration.

4. Press the

Save and Exit

softkey.

5. Return the

920i

to setup mode.

6. Continue configuration of the indicator as described in the

920i

Installation Manual.

Other

iQUBE

-

920i

functions and setup information are described in the sections listed below:

Calibration: see Section 5.0 on page 31

Contact information: see Section 7.3 on page 40

Diagnostic setup: see Section 3.4.2 on page 25 and Section 6.0 on page 34

Alert messaging: see Section 7.0 on page 38

3.3

Configuration and Calibration Summary

Figure 3-1. Configuration and Calibration Summary

Config

Serial Port

Associate

Scale

Config

Scale

Calibr

Calib

Step 1

Step 2

Step 3

Step 4

Step 5

Port

Number

Config

Cells

Download

to J-Box

Platform

System

iQUBE

Port

Grads

Format

WZero

Theoretical

Calibration

Cal-

Match

WVal

Final

Calibration

(WSpan)