2 iqube submenu, iqdiag parameters, Iqube submenu, iqdiag parameters, S diagnostic routines – Rice Lake Digital/Diagnostic - iQube User Manual
Page 28: Iqube, Figure 3-3. iqdiag submenu
Advertising
920i Indicator Configuration
25
3.4.2
iQUBE Submenu, IQDIAG Parameters
Figure 3-3 shows the IQDIAG parameters on the IQUBE submenu. The IQDIAG parameters allow
customization of the
iQUBE
’s diagnostic routines.
Figure 3-3. IQDIAG Submenu
IQDIAG
ZEROREF
number
THRH
number
%THRH
number
DELAY
0.125000
25
900
CELLEMU
DIGIO
TESTCOM
OFF
ENABLE
ON
If ENABLE = ON
number
THRH
number
%TOLR
number
LOAD
0.200000
25
5000.000
OFF
ENABLE
ON
If ENABLE = ON
CELLBAL
LDRIFT
number
LIMIT
number
%LIMIT
number
TIME
0.025000
10
30
OFF
ENABLE
ON
If ENABLE = ON
number
LOAD
5000.000
PKtoPK
number
LIMIT
0.125000
OFF
ENABLE
ON
If ENABLE = ON
MOTBAND
number
10.00000
AUTO2
TYPE
AUTO1
OFF
ENABLE
ON
If ENABLE = ON
MANUAL2
MANUAL1