1 system configurations and options – Rice Lake Digital/Diagnostic - iQube User Manual

Page 5

Advertising
background image

2

iQUBE

Installation Manual

Configuration consists of the following steps:

Define Load Cells: This is the electrical sensitivity
(mV/V output) and capacity specification of the load
cells. Load cell names and serial number can also be
specified.

Define Platforms: A platform is a contiguous weigh
bridge. Any

iQUBE

board can assign load cells to two

separate platforms. A maximum of four platforms can
be defined in an

iQUBE

system. The relationship

between load cells is also defined as a paired or
circular arrangement.

Define Systems: The platforms can be assigned to a
system. Up to four unique systems can be defined,
however the

920i

will only support one system per

serial channel.

Load Cell Trimming and Calibration

Cal-Match

calibration calculates the load cell trim

based on a comparison of the signal generated by an
applied weight for each load cell to the signal
generated by all other load cells. If a known test
weight value is used, this calibration also sets the span
for the scale.

T h r e e t y p e s o f C a l - M a t c h c a l i b r a t i o n c a n b e
performed using the

iQUBE

. Each type of calibration

captures the initial dead load of the scale and provides
a means to trim the outputs of the load cells.

Cal-Match Theoretical calibration allows each cell
to be zeroed and trim factors calculated. Based on the
cell capacity and sensitivity, the

iQUBE

calculates

weight values based on the total signal from all of the
cells.

Cal-Match Section calibration requires a weight to
be placed over each section. Trimming can be
performed by running a weight cart down the middle
of the platform, stopping for calibration of each
section.

Corner calibration requires weight to be placed over
each cell individually. Corner trimming can be
performed for platforms using an even or odd number
of cells.

Diagnostics (Error 2)

Diagnostic functionality can be enabled for the

iQUBE

to identify abnormal load cell outputs. This is based
on the reference established through cell associations.
The diagnostic conditions that can be identified for
paired configurations are open bridge or channel, zero
reference tolerance, drifting, peak-to-peak noise, and
out-of-balance conditions. Diagnostic conditions
recognized for circular configurations are limited to
open bridge or channel, drifting, and peak-to-peak
noise.

Error conditions generate a displayed error message if
connected to the

920i

which, with an Ethernet card,

can be configured to e-mail the alert message to an
address. In addition, there is a visual LED indication
on the connector board to identify any load cell that
appears to have an abnormal condition.

Cell Emulation

Cell emulation allows the output of a failed load cell
to be emulated. Automatic or manual cell emulation
can be specified (limited to one cell per scale system),
using either truck scale (Type 1) or tank/hopper/floor
scale (Type 2) emulation algorithms.

NOTE: Satisfactory results from cell emulation require the
load to be centered and the scale installation to be plumb and
level.

1.1

System Configurations and Options

Table 1-1 lists

iQUBE

model and option part numbers.

920i

part numbers listed are for models without A/D

cards.

Model / Option

PN

4-channel

iQUBE

92391

8-channel

iQUBE

92392

8-channel

iQUBE

with digital I/O

92393

iQUBE

internal power supply, 6 VDC

77531

iQUBE

internal Ethernet interface

77142

iQUBE

internal fiber-optic interface

77143

920i

internal fiber-optic interface

77788

920i

internal Ethernet communications card

71986

920i

Serial option card

67604

Remote (external) fiber-optic interface

77789

Analog output, 0–30 mV

77146

Analog output, 0–20 mA (passive)

77797

920i

universal model, 115 VAC

77790

920i

universal model, 230 VAC

77791

920i

deep enclosure, wwithout A/D model,

115 VAC

93243

920i

deep enclosure, wwithout A/D model,

230 VAC

93244

920i

panel mount model, 115 VAC

77792

920i

panel mount model, 230 VAC

77793

920i

wall mount model, 115 VAC

77794

920i

wall mount model, 230 VAC

77795

Table 1-1.

iQUBE Model and Option Part Numbers