4 software version updates, 5 specifications, 4 software version updates 9.5 specifications – Rice Lake Digital/Diagnostic - iQube User Manual

Page 53: Iqube, Power, A/d specifications, Serial communications, Environmental, Enclosure, Certifications and approvals

Advertising
background image

50

iQUBE

Installation Manual

22. Replace the two jumpers J3 that were removed in step 2.

23. Place new label, 2145 on the CPU chip.

9.4

Software Version Updates

9.5

Specifications

Power

Power Consumption (+6 VDC)

4-channel, 4 x 350

Ω load cells 91 mA (0.546 W)

8-channel, 8 x 350

Ω load cells 134 mA (0.810 W)

Fuse

2A TR5 subminiature fuse
Wickmann Time-Lag 19374 Series
UL Listed, CSA Certified and Approved

A/D Specifications

Excitation Voltage

4 VDC (+4V and ground, single-sided)

Analog Signal Input Range

–11.7 mV to +27.3 mV

A/D Sample Rate

15 Hz per channel

Serial Communications

J7 Port

Full duplex RS-232 or RS-485. Can be routed
through J6 for Ethernet or fiber-optic cabling.

J4 Port

4-wire RS-485 only

Environmental

Operating Temperature –10 to +40°C (14 to 104°F)
Storage Temperature

–10 to +70°C (14 to 158°F)

Humidity

0–95% relative humidity

Enclosure

Enclosure Dimensions 11.5 in x 8.25 in x 5.25 in

29 cm x 21 cm x 13 cm

Weight

8.0 lb (4 Kg)

Rating/Material

NEMA 4X

Certifications and Approvals

NTEP
CoC Number

03-032

Accuracy Class

III/IIIL

n

max

: 10 00000

UL
File Number:

E151461

Version Number

Update

10243

Initial Release

12283

Protocol chagne from iQUBE - requires 920i version 2.01

05054

Remote diagnostic LED error corrected

Reordering of the captured Cal-Match matrix

Emmulator 2 added

06254

(Not released)

Improved Cal-Match for small changes in load cell output

Changed operation of temperture compensation

0704a

Corrected communication problem between core module and remote
boards

0714b

Corrected the remote boeard intermittent communicaton problem

2145

Changed master error bit polarity

Operation of temperature compensation

Communications handshaking

Selection of baud rates