Rice Lake Digital/Diagnostic - iQube User Manual

Page 27

Advertising
background image

24

iQUBE

Installation Manual

SOURCE

OFF
system_name

Analog output source. If analog output DAC is installed, assign system name.

FULLSC

300000.0
value (weight)

Analog output full scale range. Specifies the weight value at the full scale analog output
(30 mV or 20 mA).

BIT 1 – BIT 8

Specifies the function of the digital I/O bit. See the

920i

Installation Manual, PN 67887,

for more information.

ZEROREF

ENABLE
THRH
%THRH
DELAY

Zero reference diagnostic subparameters. See Table 3-2 on page 26. The zero reference
test compares the millivolt output of section pairs when half of the load cell outputs are
below the specified threshold value.

CELLBAL

ENABLE
THRH
%TOLR
LOAD

Cell balance tolerance diagnostic subparameters. See Table 3-2 on page 26. The cell
balance test checks the outputs of section pairs for equal load distribution.

LDRIFT

ENABLE
LIMIT
%LIMIT
TIME
LOAD

Load cell drift diagnostic subparameters. See Table 3-2 on page 26.

PKtoPK

ENABLE
LIMIT

Peak-to-peak diagnostic subparameters. See Table 3-2 on page 26.

CELLEMU

ENABLE
TYPE

Cell emulation. See Table 3-2 on page 26 for more information.

MOTBAND

10.00000
value (weight)

Motion band. See Table 3-2 on page 26 for more information.

SERIAL Menu (

iQUBE Submenu)

Parameter

Choices

Description

Table 3-1. Serial Menu Parameters,

iQUBE Submenu (Continued)

Advertising