Diagnostic Setup

Parameters associated with each of the

iQUBE

’s

diagnostic tests can be set using the

920i

menus,

iRev

,

or

Revolution III

. See Section 3.4.2 on page 25 for

descriptions of the

iQUBE

diagnostic parameters for

the

920i

.

Figure 6-5.

Revolution III Diagnostic Setup Display

6.4.1

Configuring the 920i Diagnostics Softkey

When using the

iQUBE

with the

920i

indicator, a

Diagnostics

softkey can be configured to display

diagnostic information when in weigh mode. Use the
FEATURE menu, SOFTKEYS submenu, to select the
Diagnostics softkey (see Figure 6-6).

Figure 6-6. Selecting Diagnostics Softkey

6.4.2

920i Diagnostic Display

Figure 6-7 shows an example of a

920i

display of

iQUBE

diagnostic information. Information shown

includes the following:

Cell name

Cell deadload value (mV)

Current individual cell and total values (mV)

Number of weighments

Cell status for highlighted cell. Use the
indicator navigation keys to select cells.

NOTE:

Displayed deadload and current values are raw

millivolt values. All diagnostic measurements use
corrected mV values:

corrected_value = current_value – deadload_value

Figure 6-7.

920i Diagnostic Display

The

920i

diagnostic display can be shown by pressing

the

Diagnostic

softkey (if configured).

In setup mode, diagnostic information can be shown
by going to the VERS menu., pressing the

Contact

softkey, then the

Next

softkey.

Access through the VERS menu also displays
softkeys for

Clear Diagnostics

and, if cell emulation is

enabled,

Cell Emulation

. If cell emulation is set to

AUTO2 or MANUAL2 (see page 27), a

Snapshot

softkey is also shown.

6.5

Error Messages

Table 6-3 shows the alert system status messages
generated by the

iQUBE

.

Error messages are displayed on the indicator and can
be used by print formats and

iRite

user programs.

Scale

Number

Status Message

Cell Error

Messages

Cell ID

Scale x

System boundary error:
Weighing error:
Master error:

Error 1 Cell
Error 2 Cell
Error 3 Cell

An,Bn,Cn
,