PC Configuration

29

4.0

PC Configuration

When used with the

920i

indicator, the

iQUBE

can be configured using a PC running either the

iRev

or the

Revolution III

program.

iRev

allows complete configuration of the

920i

, with the capability to download the

iQUBE

configuration from the indicator to the junction box.

Revolution III

can be used to configure the

iQUBE

directly, for use with any indicator.

iQUBE

configurations created using

Revolution III

can be uploaded to the

920i

.

4.1

Using Revolution III

The

Revolution III

configuration utility can be used to

set

iQUBE

configuration parameters for use with any

indicator. When

Revolution III

configuration is

complete, configuration data is downloaded to the

iQUBE

.

R e v o l u t i o n I I I

s u p p o r t s b o t h u p l o a d i n g a n d

downloading of

iQUBE

configuration data. This

capability allows configuration data to be retrieved
from one

iQUBE

, edited, then downloaded to another.

Revolution provides online help for each of its
configuration displays.

To use

Revolution III

, do the following:

1. Install

Revolution III

on an IBM-compatible

personal computer running Windows

®

98 or

later. Minimum system requirements include a
processor speed of at least 166MHz, 32MB of
memory (64MB recommended, required for
NT4, 2000, XP), and at least 40MB of available
hard disk space for installation.

2. With both the

iQUBE

and the PC powered off,

connect the PC serial port to pins 2, 3, and 6 of
connector J7 on the

iQUBE

connector board.

(See Figure 2-2 on page 4 and Figure 2-4 on
page 7)
.

3. Power up the PC and the

iQUBE

. Use the setup

switch to place the

iQUBE

in setup mode.

4. Start the

Revolution III

program.

4.1.1

Revolution III Configuration

To configure the

iQUBE

using Revolution, do the

following:

1. With the PC and

iQUBE

connected and the

Revolution III program running, select

New

from the File menu.

2. On the Select Indicator display, highlight the

iQUBE

icon, for the correct core version, see

Figure 2-2 on page 4, click the radio button
for

New Configuration File

, then click

OK

. The

iQUBE

Information Display is shown.

3. Select

Configuration

from the left-hand tool

bar on the

iQUBE

Information Display (see

Figure 4-1). The Configuration submenu is
shown.

Figure 4-1. Revolution

iQUBE Display

4. Select

Core

. Use this screen to set the Auto

Transmit Port and section type. Note: As you
set up

iQUBE

you will be moving down

through the configuration menu pages.

5. Select the

Cells Configuration

display. Use this

display to select the load cells used in the

iQUBE

system by checking the box to the left

of each cell. Enter load cell data such as
factory sensitivity, serial numbers, and
capacity on the General Information sheet for
each cell.

6. Select the

Platforms Configuration

display.

Cells that were checked on the Cells screen
are now listed as Available Load Cells for the

iQUBE

.

7. Click on

Platform 1

.

8. Double-click on each available load cell to

move the cell into the Assigned Load Cell
column for Platform 1.

NOTE: You can rearrange the Assigned Cells by
clicking on individual cells and then using the up or
down arrows to change the position of the cell.

As cells are added to the Assigned Cell
column, a Section Format Diagram is
displayed at the bottom of the screen.

9. Select the

Systems

display.

10. Click on

System 1

.

11. Platform 1 is now shown in the Assigned

Advertising