4 920i internal fiber-optic option, 15 fuse replacement, 16 parts kit contents – Rice Lake Digital/Diagnostic - iQube User Manual

Page 19: 920i internal fiber-optic option, 15 fuse replacement 2.16 parts kit contents, V2 v1

Advertising
background image

16

iQUBE

Installation Manual

2.14.4

920i Internal Fiber-Optic Option

To install the

920i

internal fiber-optic interface,

position the adhesive square on the top of the

920i

power supply shield (see Figure 2-14 on page 14).
Press the fiber-optic interface backplate onto the
adhesive square, then install the interface board onto
the backplate.

Attach fiber-optic cables to connectors V1 (receive)
and V2 (send). Attach RS-232 communications cables
from connector J3 on the fiber-optic interface to any
available

920i

serial port. Use cable ties to secure

communications cables inside the indicator enclosure.

Power to the

920i

internal fiber-optic interface is

provided by tap and run connectors on the +6V and
GND wires between the

920i

power supply and the

indicator CPU board. Attach power supply wires to
connector J4 on the fiber-optic interface. See
Section 2.12 on page 14 for installation information.

Figure 2-18.

920i Internal Fiber-Optic Option Card

2.15 Fuse Replacement

F u s e F 1 o n t h e

i QU B E

c o n n e c t o r b o a r d ( s e e

Figure 2-2 on page 4) provides protection for power
supplied to the connector board and core module at
connector J10. See Section 9.5 on page 50 for
complete fuse specifications.

To protect against the risk of fire, replace
fuses only with same type and rating fuse.

2.16 Parts Kit Contents

Table 2-8 lists the parts kit contents for the

iQUBE

.

V2

V1

(BLACK)

(BLUE)

TRANSMITTER

DETECTOR

J4

1

J3

1

+6V

GND

RXD

TXD

GND

POWER

SERIAL DATA

PN

Description

15631

Cable ties, 3-in. nylon (15)

15650

Cable tie mounts, 3/4-in. (7)

15665

Reducing glands, 1/2-in. NPT (10)

19538

Cord grip plugs (6)

42350

Capacity label (1)

60940

120

Ω resistors for RS-485 termination (2)

67063

Enclosure mounting tabs (4)

71349

1-in. polycarbonate breathing filter (1)

77925

Revolution III

configuration software CD (1)

78476

Cage clamp tools for load cell connectors (2)

80331

Tap and run connectors (2)

83937

iQUBE

Technical video (1)

77224

Installation manual (1)

Table 2-8. Parts Kit Contents