Calibration

31

5.0

Calibration

The

iQUBE

can be calibrated using the

920i

front panel or

Revolution III

. The following sections describe the

calibration procedure for each of the calibration methods.

Figure 5-1. CALIBR Submenu

5.1

920i Front Panel Calibration

The CALIBR submenu (under the SCALES menu,
see Figure 5-1) is used to calibrate the

920i

and the

iQUBE

at the same time.

Three calibration methods can be used to trim the load
cells:

Theoretical

Cal-Match

Manual trimming

5.1.1

Theoretical Calibration

To perform a theoretical calibration of the

iQUBE

using the

920i

front panel, press the

Theoretical

Calibration

softkey. The dead load value is captured

and the cells trimmed based on the capacity and
sensitivity values entered for the cells. Scale capacity
is set at the total of the load cell capacities.

5.1.2

Cal-Match Calibration

To perform a Cal-Match calibration of the

iQUBE

using the

920i

front panel, do the following:

1. Place the indicator in setup mode (display

reads

Scale Configuration

) and remove all

weight from the scale platform.

2. With the SCALES menu highlighted, press

the

down

key to show the CALIBR parameter.

3. From the CALIBR parameter, press

down

again to show a list of configured platforms
and select the platform to be calibrated.

4. Press

down

to go to the test weight parameter

(

WVAL

). By default, the test weight value is set

to the total load cell capacity. Use the numeric
keypad to enter the test weight, then press

enter

.

5. Press the

Cal-Match

softkey to continue

WZERO

WVAL

WSPAN

WLIN

REZERO

POINT 4

POINT 5

POINT 1

POINT 2

POINT 3

VISIBLE

GRADS

FORMAT

CALIBR

CALIB

SECTIONS

CORNERS

WZERO

display

List of

platforms

PLAT x

Sections

display/tweak

Corners

display/tweak

Deadload

adjustment

weight_value

Theoretical
Calibration

SCALES

SERIAL

FEATURE

PFORMT

SETPTS

DIG I/O

ALGOUT

VERS

SCALE x

If

SECTION=PAIRED

mV_value

NOTE: Perform Corner
or Section-Match

Advertising