Caution

Etanorm SYA

4

1

General

This KSB pump has been developed in accord-
ance with state-of-the-art technology; it is

manufactured with utmost care and subject to continuous qual-
ity control.
These operating instructions are intended to facilitate familiar-
ization with the pump and its designated use.
The manual contains important information for reliable, proper
and efficient operation. Compliance with the operating instruc-
tions is of vital importance to ensure reliability and a long service
life of the pump and to avoid any risks.
These operating instructions do not take into account local reg-
ulations; the operator must ensure that such regulations are
strictly observed by all, including the personnel called in for in-
stallation.

This pump / unit must not be operated beyond the limit
values specified in the technical documentation for the

medium handled, capacity, speed, density, pressure, tempera-
ture and motor rating. Make sure that operation is in accordance
with the instructions laid down in this manual or in the contract
documentation. (Contact the manufacturer, if required.)
The name plate indicates the type series / size, main operating
data and works number; please quote this information in all
queries, repeat orders and particularly when ordering spare
parts.
If you need any additional information or instructions exceeding
the scope of this manual or in case of damage please contact
KSB’s nearest customer service centre.
For noise characteristics please refer to section 4.5.

2 Safety

These operating instructions contain fundamental information
which must be complied with during installation, operation and
maintenance. Therefore this operating manual must be read
and understood both by the installing personnel and the re-
sponsible trained personnel / operators prior to installation and
commissioning, and it must always be kept close to the location
of operation of the machine / unit for easy access.

Not only must the general safety instructions laid down in this
chapter on ”Safety” be complied with, but also the safety
instructions outlined under specific headings.

2.1 Marking of Instructions in the Manual
The safety instructions contained in this manual whose non-
observance might cause hazards to persons are specially
marked with the general hazard sign, namely

safety sign in accordance with DIN 4844 - W9.

The electrical danger warning sign is

safety sign in accordance with DIN 4844 - W8.
The word

is used to introduce safety instructions whose non-observance
may lead to damage to the machine and its functions.
Instructions attached directly to the machine, e.g.
- arrow indicating the direction of rotation
- markings for fluid connections
must always be complied with and be kept in perfectly legible
condition at all times.

2.2 Personnel Qualification and Training

All personnel involved in the operation, maintenance, inspec-
tion and installation of the machine must be fully qualified to
carry out the work involved.
Personnel responsibilities, competence and supervision must
be clearly defined by the operator. If the personnel in question is
not already in possession of the requisite know-how, appropri-
ate training and instruction must be provided. If required, the op-
erator may commission the manufacturer / supplier to take care
of such training. In addition, the operator is responsible for en-
suring that the contents of the operating instructions are fully
understood by the responsible personnel.

2.3 Non-compliance with Safety Instructions

Non-compliance with safety instructions can jeopardize the
safety of personnel, the environment and the machine itself.
Non-compliance with these safety instructions will also lead to
forfeiture of any and all rights to claims for damages.

In particular, non-compliance can, for example, result in:

-

failure of important machine / unit functions

-

failure of prescribed maintenance and servicing practices

-

hazard to persons by electrical, mechanical and chemical
effects

-

hazard to the environment due to leakage of hazardous
substances.

2.4 Safety Awareness

It is imperative to comply with the safety instructions contained
in this manual, the relevant national health and safety regula-
tions and the operator’s own internal work, operation and safety
regulations.

2.5 Safety Instructions for the Operator / User

-

Any hot or cold components that could pose a hazard must
be equipped with a guard by the operator.

-

Guards which are fitted to prevent accidental contact with
moving parts (e.g. coupling) must not be removed whilst
the machine is operating.

-

Leakages (e.g. at the shaft seal) of hazardous media han-
dled (e.g. explosive, toxic, hot) must be contained so as to
avoid any danger to persons and the environment. Perti-
nent legal provisions must be adhered to.

-

Electrical hazards must be eliminated. (In this respect refer
to the relevant safety regulations applicable to different
countries and/or the local energy supply companies.)

2.6 Safety Instructions for Maintenance, Inspection and

Installation Work

The operator is responsible for ensuring that all maintenance,
inspection and installation work be performed by authorized,
qualified specialist personnel who are thoroughly familiar with
the manual.
The pump must have cooled down to ambient temperature.
Pump pressure must have been released and the pump must
have been drained.

93