Etanorm sya – B&C Technologies IM Series Industrial Ironer User Manual

Page 112

Advertising
background image

Cover plate

1211:117

Cover plate

400

210

360

321

330

1215:7

Cover plate

400

210

360

321

330

1215:8

Caution

Etanorm SYA

13

Additional instructions:
- Place joint ring 411.4 on discharge cover sealing face, to

prevent it from slipping out of position.

- Replace all joint rings and gaskets affected by dismantling.
- Use specified deep-groove ball bearing 321 only.
- Pack bearing with grease (see 7.2.2.3)
- When fitting the deep-groove ball bearing, ensure the side

with the cover plate points towards the pump side (see figs.
7.5-1, 7.5-2, 7.5-3)

Etanorm SYA SU 25

1)

Fig.7.5-1 Mounting the deep-groove ball bearing,shaftunit 25

1)

1) For shaft unit/pump size combinations see section 7.6.1

Etanorm SYA, SU 35

1)

Fig. 7.5-2 Mounting the deep-groove ball bearing SU 35

1)

1) For shaft unit/pump size combinations see 7.6.1

Etanorm SYA, SU 55

1)

Fig. 7.5-3 Mounting the deep-groove ball bearing SU 55

1)

1)

For shaft unit/pump size combinations see 7.6.1

Replacing the plain bearing

- Removing the shaft and the plain bearing

Remove shaft 210 from bearing bracket 330 towards the
coupling.
Press plain bearing 310 out of the bearing bracket.

- Mounting the plain bearing

Carefully press plain bearing 310 into bearing bracket 330 up
to the stop.

Maximum clearance at plain
bearing:

As-new clearance at plain
bearing:

SU 25

1)

0.35 mm

SU 35, 55

1)

0.4 mm

0.08 - 0.13
0.08 - 0.13

- If the sealing area between the impeller neck and the casing

wear ring is worn, causing an excessive sealing clearance

0.9 mm, the casing wear rings (502.1 and 502.2, if fitted)

must be replaced. The as-new clearance between casing
wear ring and impeller is 0.3 mm on diameter.

1)

For shaft unit/pump size combinations see 7.6.1

7.5.2

Mechanical seal

Reassembly is effected in reverse order to dismantling.
The following rules shall be observed when mounting the me-
chanical seal:
Extreme care and cleanliness.
The protective wrapping of the contact faces must only be re-
moved immediately before assembly takes place.
Take care not to damage the seal faces and the O-rings.
Clean the shaft and the seat ring holder and carefully remove
any deposits.

102