B&C Technologies IM Series Industrial Ironer User Manual

Page 142

Advertising
background image

16

ELECTRICAL CONNECTIONS

Use flexible cables according to local Regulations.

LAYOUT (A) - The RS 28/M - RS 38/M models
electrical connection single-phase power supply

LAYOUT (B) - The RS 38/M - 50/M models
electrical connection three-phase power supply

Fuses layout (A) - (B), see table (C).
Wire size when not indicated: AWG18.

KEY TO LAYOUTS (A) - (B)
IN

- Burner manual stop switch

MB

- Burner terminal strip

PG

- Min. gas pressure switch

PS

- Remote lock-out reset

H1

- Remote lock-out signal

H2

- Burner on signal

H4

- Power on signal

H5

- Permission ok

OCR - High-low control.
OC

- Operating control.

HL

- High limit.

Y0

- Pilot valve

Y10

- Adjustment valve

Y11

- Safety valve

Y13

- Pilot valve (safety)

LAYOUT (D)
Connection of RWF40 and related probe to RS 28-
38-50/M burners (modulating operation)

Note
The OCR and OC controls are not required when the
PID control RWF40 is connected, as their function is
performed by the RWF40 itself.

It can be connected to the terminals:
- T1 -T2, to replace the remote control TL

Key to layout (D)
BT - Temperature probe
BP - Pressure probe
MB - Burner terminal strip
a

- Red

b

- Red

c

- White

d

- White

NOTES
• The setting of the thermal overload must be according

to the total burner amperage draw.

• Models RS 38-50/M leave the factory preset for 208 -

230 V power supply. If 460 V power supply is used,
change the motor connection from delta to star and
change the setting of the thermal cutout as well.

• Models RS 28-38-50/M have been type- approved for

intermittent operation. This means they should com-
pulsorily be stopped at least once every 24 hours to
enable the control box to check its own efficiency at
start-up. Burner halts are normally provided for auto-
matically by the boiler load control system.
If this is not the case, a time switch should be fitted in
series to IN to provide for burner shut-down at least once
every 24 hours.

(A)

(B)

RS 28/M

RS 38/M

Single-

phase

RS 38/M

Three-phase

RS 50/M

120 V

120 V

208 -

230 V

460 V

460 V

208 -

230 V

460 V

575 V

F

A

T10

T10

T6

T6

T4

T6

T6

T4

(C)

(D)

D2322

RWF40

D2271

D2272

Field Wiring Diagram
RS 28/M - RS 38/M Single-phase
with burner mounted Siemens LFL control

Field Wiring Diagram
RS 38/M - RS 50/M Three-phase
With Burner mounted Siemens LFL control