Install the drive motor assembly at the rear right-hand side of the ironer. Align the drive pulleys
with the driven pulleys using a steel straight-edge. Anchor the drive unit to the floor. Install the
V-Belts between the drive pulleys and the driven pulleys.

Secure the machine to the floor or foundation if required by local codes.

*ACCESS LADDER (OPTIONAL)

Install the access ladder to the rear mounting position. Ensure

the assembly bolts are tight to prevent any accidents! Only authorized technicians are permitted
access to the top of the machine

*SAFETY RAILINGS (OPTIONAL)

Install the safety railing to the machine ensure installation is

secure before technicians again access to the machine top.

3.6

Compressed Air Connections

3.6.1

Internal Connections

On each side of the machine in the electrical raceways, compressed air connections must be made.
Follow the numbering scheme to connect the air lines correctly.

3.6.2

External Connection

The IM Series ironers require compressed air in order to raise and lower the rolls. Clean, dry
compressed air must be provided at a minimum pressure of 65PSI (4.5 bar). A 3/8NPT connection
is provided on the right side of the front (infeed) module.

3.7

Electrical Connections

3.7.1

Internal Electrical Connections

There are multiple connections to be made between modules before main power can be applied,
including control cabling, temperature probe cabling, and burner cabling.

Note: Only a qualified electrician should complete the electrical connections inside the ma-
chine. Improper connections could lead to improper operation and serious injury. Do not con-
nect main power to the machine until all internal connections are complete and verified.