Operation, Operating procedure, Daily inspection – B&C Technologies IM Series Industrial Ironer User Manual

Page 43: Chapter 4 operation, 1 operating procedure

Advertising
background image

Chapter 4

Operation

4.1

Operating Procedure

4.1.1

Perform Daily Inspection

1. Walk around machine and look for oil leaks, make sure the folder is in place, look for any

loose parts and hazards.

2. Check the guide tapes. If there are many broken they should be replaced when the machine

is cold.

3. Check the oil level. When the ironer is cold the level should be in the bottom 1/4 of the sight

glass. When the machine is hot the oil will expand to 3/4 on the sight glass.

4. On the left control panel make sure the burner is off (green switch) and the oil pump switch

is in the automatic position.

5. On the right control panel make sure all Roll switches are in the up position and the Blower

is in the off position.

6. On the right control panel push the green on button. The machine will power up and the

oil pump should start. Listen to the sound of the pump for irregular sounds or vibration.
If you hear anything abnormal (slurping sounds, excessive vibration, etc.) please call for an
inspection.

7. On the left control panel set the burner switch to on, and make sure the temperature is set

for 330

o

F on the lower display.

8. When the burner lights the Heating On lamp will be lit. If there is a problem, one of the

burner / alarm or low pressure / Gas lamp will turn on. If the burner alarm turns on, then
you can press the burner reset button on the right panel to restart the burner If you have to
reset the burner regularly please call for service.

9. The machine will take about 30 minutes to heat up (depending on how cold it was). During

this time review the waxing procedures and prepare to wax the machine.

33