B&C Technologies IM Series Industrial Ironer User Manual

Page 130

Advertising
background image

4

BURNER DESCRIPTION (A)

1 Combustion head
2 Ignition electrode
3 Screw for combustion head adjustment
4 Sleeve
5 Low air pressure switch

(differential operating type)

6 Flame sensor probe (flame rod)
7 Air pressure test point
8 Gas pressure test point and head fixing screw
9 Screws securing fan to sleeve
10 Slide bars for opening the burner and inspecting the

combustion head

11 Servomotor controlling the gas butterfly valve and air

damper (by means of a variable profile cam mecha-
nism).
When the burner is not operating the air damper is
fully closed in order to reduce heat loss.

12 Plate with four hole knock-outs for electrical cable

routing

13 Air inlet to fan
14 Gas input connection
15 Gas butterfly valve
16 Boiler mounting flange
17 Flame stability disk
18 Flame inspection window
19 Ignition pilot
20 Motor contactor and thermal overload reset button

(RS 38 - 50 three-phase)

21 Plug-socket on flame rod probe cable
22 Flame safeguard
23 Power switch for different operations:

automatic - manual - off
Switch for:
manual modulation of servomotor

24 Burner terminal strip
25 Air damper
26 Bracket for mounting the PID modulating controller

RWF40 (optional)

Two types of burner failure may occur:

FLAME SAFEGUARD LOCK-OUT:

if the flame relay 22)(A) pushbutton lights up, it indi-
cates that the burner is in lock-out.
To reset, press the pushbutton.

MOTOR TRIP

(RS 38 - 50 three-phase):

release by pressing the pushbutton on thermal over-
load 20)(A).

PACKAGING - WEIGHT (B)

- Approximate measure-

ments
• The burners are shipped in cardboard boxes with the

maximum dimensions shown in Table (B).

• The weight of the burner complete with packaging is

indicated in table (B).

MAX. DIMENSIONS (C)

Approximate measurements
The maximum dimensions of the burners are given in
(C).
Note that if you need to examine the combustion head,
the burner must be pulled backward on the slide bars
and turned upward.
The maximum dimension of the burner, without the
cover, when open is give by measurement H.

STANDARD EQUIPMENT

1 - Gas train flange
1 - Flange gasket
4 - Flange fixing screws
1 - Burner head gasket
4 - Screws to secure the burner flange to the boiler:

3/ 8

W x 1”

1 - Instruction booklet
1 - Spare parts list

(A)

inch

A

B

C

lbs

RS 28/M

39

31/32

24

13/16

19

11/16

84

RS 38/M

39

31/32

24

13/16

19

11/16

88

RS 50/M

39

31/32

24

13/16

19

11/16

91

D88

(B)

(1) Blast tube: short - long (with kit)

RS

A

B

C

D

(1)

E

F

G

H

I

L

M

28 18

23/32

“ 18

21/32

“ 22

13/16

“ 8

1/2

-13

13/16

5

1/2

“ 13

27/32

“ 6

7/16

“ 31

7/8

“ 4

1/4

“ 6

5/8

“ 1

1/2

38 18

23/32

“ 18

21/32

“ 22

13/16

“ 8

1/2

“-13

13/16

5

1/2

“ 13

27/32

“ 6

7/16

“ 31

7/8

“ 4

1/4

“ 6

5/8

“ 1

1/2

50 18

23/32

“ 18

21/32

“ 22

13/16

“ 8

1/2

“-13

13/16

“ 5

31/32

“ 13

27/32

“ 6

7/16

“ 31

7/8

“ 4

1/4

“ 6

5/8

“ 1

1/2

(C)

D2256

D2257

D2258

D495

120

Advertising