module, controls the pressure which is monitored via a pressure gauge on the left control
panel. As an option, individual pressure control of each roll is available.

10. Linen Infeed

The infeed of linen occurs on the front side of the ironer via wear and temperature resistant
flat belts. The belts are driven by a textured infeed roller. A finger guard, located at the end
of the belts, stops the ironer and lifts the first roller immediately if activated.

11. Utility Connections (when looking from the front)

Electricity

Type 800

Left side

Type 1200

Right side

Compressed Air

Type 800

Right side

Type 1200

Left side

Exhaust

Type 800

Right side

Type 1200

Left side

12. Control Panels

The left control panel includes emergency stop button, roll temperature, air pressure for each
roll, steam inlet temperature, steam pressure The right control panel includes rate meter,
speed selector lift and lower switch for each roller, switch for on and start, push button drive
on, pilot light for main power, pilot light for overload, pilot light for control, push button for
control, jog button (reverse), drive start push button, emergency stop and selector switch.

13. Electrical Components

The electrical panel is located at the right side for model 1200 and Left side for model 800
of the first module in an enclosure with a door that can only be open by a special key. All
electrical components on the panel are DIN rail mounted for easy repair and maintenance.
The serial plate is located on the left side in the enclosure.

14. Safety Features

The infeed side is protected by a windowed heat-resistant finger guard that, if activated,
will instantly stop the drive motor and raise the first roll. Two emergency push buttons are
located at either end of the ironer and should only be used in emergencies. If activated,
these emergency buttons will shut off the ironer and raise all the rolls. All mechanical and
electrical components are covered by sheet metal panels or located behind enclosures. Panels
and service doors can only be opened with special keys.

15. Optional Canopies

Canopies can be provided so that heat losses are reduced to a minimum. The canopies are of
aluminum construction.

3.2

Electrical & Gas Specifications

Refer to Table 3.1 for complete details on gas and electrical requirements. Gas must be provided
between 1/2 and 2 PSI, with gas piping provided to meet the volume of gas required. Best re-

10