4.

Configure required timers:

Provisional Timer is the time interval for which the phone waits for the call initiation
acknowledgement from the remote side. This timer is started when the call is initiated. This timer is
useful in situations where the remote phone is unreachable for unknown reasons. The default value
is set to five seconds. This timer is used only during round robin dialing.

Ringer Timer is the number of rings (one ring = six seconds) the phone waits before dialing the next
number. The default value is five rings. This timer is used only during round robin dialing.

Hang-up Timer is the time interval for which the phone waits before initiating a new call after
hanging up the current call. The default value is 0.5 seconds.

Local Inter-digit Timer is the time interval between two consecutive dialed digits. The inter-digit
timer is started when the first digit is entered and is restarted after each new digit is entered. When
the user dials a number, a call gets initiated after the expiry of this timer. This timer also applies
during local key code translations for performing the operations. The default value is five seconds.

Remote Inter-digit Timer is the time interval for which the phone is expecting a digit to be received
from remote side during key press to answer and for DTMF Operation Codes

3

that require remote

key codes for activation/deactivation. The default value is five seconds.

5.

Configure optional timers:

Call Conversation Timer is the time interval after which the call is terminated automatically. The
default value is 12 minutes. If the call conversation time is disabled the conversation lasts for an
indefinite duration.

Ringback or Busy Timer is the time interval for which the phone waits on the call queue before
dialing the next number from the number list. The default value is 15 seconds. The phone waits for
indefinite time if this timer is disabled. This timer is used only during round robin dialing.

Hang-up on Silence Timer is the time interval after which a call is terminated automatically if the
voice or audio channel is idle. The default value is 30 seconds.

6.

Click Apply to save settings.

3

For example, the remote key code sequence 123 is used for activating Aux output #1.During a call, the remote side presses 12, now the

phone is expecting key 3 to be received before the expiry of this timer, if key 3 is pressed before expiry of this timer, a single beep is heard at
the remote side followed by Aux Output #1 Activation at the local end. If not, the phone considers this as an unsuccessful operation and will
play two beeps to the remote side.