++ Valid values : KeypadMode = 1 - Normal dial (Default Value)
++ KeypadMode = 2 - Speed dial
++ Note : If Keypad is in speed dial, then Admin should configure
++ the speeddial numbers (Max 30 chars) .
++ Admin can configure IP Addresses, Analog Numbers, Aliases
++ and URLs. (Max 30 chars)
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

KeypadMode = 1
SpeedDialKey0 =
SpeedDialKey1 =
SpeedDialKey2 =
SpeedDialKey3 =
SpeedDialKey4 =
SpeedDialKey5 =
SpeedDialKey6 =
SpeedDialKey7 =
SpeedDialKey8 =
SpeedDialKey9 =

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : Led3
++ Description : Admin can configure Led3 Mode for specific purposes
++ Valid values : Led3 = 1 - Help on The Way
++ Led3 = 2 - Out Of Service
++
++ Note : For Options 1 and 3, Configure following parameters
++
++ Field name : Led3SwitchOn
++ Description : Admin can configure Led3 to switch on when remote user
++ enters specific key sequence.
++ Valid values : Max 8 chars containing 0-9, * and #.
++ Default is *98*
++ Note : None
++
++ Field name : Led3DurationType
++ Description : Admin can configure Led3 duration of activation.
++ Valid values : Led3Duration = 1 - For Entire Call (Default Value)
++ Led3Duration = 2 - For indefinite duration
++ Led3Duration = 3 - For Custom duration
++ Note : If Led3Duration = 3 then configure duration time.
++
++ Field name : Led3Duration
++ Valid values : 1 - 3600 sec,in increments of 1 sec. 10 (Default Value)
++
++ Field name : Led3SwitchOff
++ Description : Admin can configure key sequence to switch off when remote
++ Admin enters specific key sequence.
++ Valid values : Max 8 chars containing 0-9, * and #.
++ Default is *97*
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Led3 = 3
Led3SwitchOn = *98*