Voip-500, Series phone configuration and operation manual – Talkaphone VOIP-500K Native VoIP Keypad Emergency Phone User Manual

Page 79

Advertising
background image

VOIP-500

Series Phone

Configuration and Operation Manual

Page 79 of 90

Copyright 2012 Talk-A-Phone Co.

• 7530 North Natchez Avenue • Niles, Illinois 60714 • Phone 773.539.1100 • [email protected] • www.talkaphone.com.

All prices and specifications are subject to change without notice. Talk-A-Phone, Scream Alert, WEBS and WEBS Contact are registered trademarks of Talk-A-Phone Co. All rights reserved.

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AuxOp1ActOnRemoteKeyCode, AuxOp2ActOnRemoteKeyCode,
++ AuxOp3ActOnRemoteKeyCode
++
++ Description : Auxiliary Output activation on specified remote keycode
++
++ Valid values : Disable,
++ Max 4 chars containing 0-9, * and #.
++ Default values are *11*, *12*, *13* correspondingly
++
++ AuxOp1ActOnRemoteKeyCode = *11* (Default value)
++ AuxOp2ActOnRemoteKeyCode = *12* (Default value)
++ AuxOp3ActOnRemoteKeyCode = *13* (Default value)
++
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

AuxOp1ActOnRemoteKeyCode = Disable
AuxOp2ActOnRemoteKeyCode = Disable
AuxOp3ActOnRemoteKeyCode = Disable

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AuxOp1ActOnLocalKeyCode,AuxOp2ActOnLocalKeyCode,
++ AuxOp3ActOnLocalKeyCode
++
++ Description : Auxiliary Output activation on specified local keycode
++
++ Valid values : Disable, Max 8 chars containing 0-9, * and #.
++
++ AuxOp1ActOnLocalKeyCode = Disable (Default value)
++ AuxOp2ActOnLocalKeyCode = Disable (Default value)
++ AuxOp3ActOnLocalKeyCode = Disable (Default value)
++
++ Note : None
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

AuxOp1ActOnLocalKeyCode = Disable
AuxOp2ActOnLocalKeyCode = Disable
AuxOp3ActOnLocalKeyCode = Disable

+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
++ Field name : AuxOp1DeActOnRemoteKeyCode, AuxOp2DeActOnRemoteKeyCode,
++ AuxOp3DeActOnRemoteKeyCode
++
++ Description : Auxiliary Output deactivation on specified remote keycode
++
++ Valid values : Disable,
++ Max 4 chars containing 0-9, * and #.
++ Default values are *21*, *22*, *23* correspondingly
++
++ AuxOp1DeActOnRemoteKeyCode = *21* (Default value)
++ AuxOp2DeActOnRemoteKeyCode = *22* (Default value)
++ AuxOp3DeActOnRemoteKeyCode = *23* (Default value)
++
++ Note : None