Change safe setting, P. 105 – Toa M-864D Ver.2.2.0 User Manual

Page 105

Advertising
background image

105

12.1. Change Safe Setting

Change safe function prevents the set parameters from being recalled when changing the Preset memory

number.

Parameters to be assigned in safe mode can be set for each of 4 layers and designated in the form of overlay

to each Preset number.

12.1.1. enabling the change safe function

Step 1. Select [Option Change Safe] from the Menu view to display the Change Safe Setting dialog.

2

Safe parameter setting (See

p. 106

. )

Memory setting (See

p. 107

.)

Step 2. Click the [Change Safe Disable] button to enable the change safe function.

A “Primary Reference Preset No. Setting” dialog is displayed.

Notes

• When the Change Safe function is enabled, no

Change Safe layer can be set for the “Primary

Reference Preset No.”

• Safe parameter settings and Memory settings

related to this function are all cleared at the time

when the Change Safe function is disabled.

Step 3. Click the Preset memory number button to be set.

The selected Preset memory number button turns

into orange.

Step 4. Click the [OK] button.

The selected Preset memory number is set to the

Preset memory at power-on.

3

4

Advertising