6. Clear Dynamic Button

Clears the set parameters of all FBS filter points

that have been automatically created when

acoustic feedback was detected in dynamic

mode.

Notes

• Protected filter points are not cleared.

• This button can be operated only while in online

mode.

7. filter Point Control

Displays the selected FBS filter point’s

parameters. At the protected point, gains and Q

values can be changed.

Filter No.

Frequency

Gain

Q

Note

The FBS filter’s parameter is automatically set

if the FBS function is set to ON. Parameters of

unprotected points cannot be changed.

8. filter Point Guard Button

Sets the guard function for the selected FBS filter

point.

The indication is displayed in yellow if “Yes” is

selected, and in gray if “No” is selected.

Notes

• For the FBS filter set to “Yes,” the filter

parameter is not updated even if the dynamic

FBS function has been set to ON with the

Dynamic Mode button. Select “Yes” when not

wishing to change the filter parameter because,

for example, it is desirable to fix the frequency

for feedback suppression.

• For the FBS filter set to “No,” the filter parameter

may be changed when feedback is newly

detected. Gains and Q values can be changed

for the guarded filter point.

9. Lock Button

Used to enable or disable the locking of gains

when dragging filter points.

Clicking “Gain Unlock” changes the indication,

locking the gain.

If the gain is locked, it becomes unchangeable

even if the filter point is dragged up and down.

Clicking the same button again restores the

previous display and releases the lock.
Note

Gains can only be locked for the filter point

operation. The gain control can be used to change

settings even while in locked mode.

10. Graph/table Display Selector Button

Switches the display of the filter control field.

“Graph”: The button is displayed in gray and

the filter control field is placed in graph

display mode.

“Table”: The button is displayed in orange and

the filter control field is placed in table

display mode.

11. Scale Setting Button

Clicking this button while the filter control field

is in graph display mode displays the dialog for

setting the graph’s scale.

E. Step settings

A. Minimum frequency settings

C. Maximum amplitude

settings

D. Minimum amplitude

settings

B. Maximum frequency settings

a. Minimum frequency Settings

Sets the minimum frequency for the graph

display (i.e. sets the left edge of the graph).

The downward pointing triangle button

decreases the frequency and the upward

pointing triangle button increases the

frequency.

Clicking the frequency indication in the center

opens the dialog for frequency entry.

B. Maximum frequency Settings

Sets the maximum frequency for the graph

display (i.e. sets the right edge of the graph).

The downward pointing triangle button

decreases the frequency and the upward

pointing triangle button increases the frequency.

Clicking the frequency indication in the center

opens the dialog for frequency entry.

C. Maximum amplitude Settings

Sets the maximum amplitude for the graph

display (i.e. sets the upper limit of the graph).

The downward pointing triangle button

decreases the amplitude and the upward

pointing triangle button increases the amplitude.

The amplitude varies by the value set in the