Toa M-864D Ver.2.2.0 User Manual

Page 69

Advertising
background image

69

[arC operating procedures]

Before Starting Operation:

Set the external equipment sound volume and other settings to actual usage conditions to ensure that sound

can be amplified at an appropriate volume level.

Note

Connect the microphone to MONO INPUT 1.

Connect the unit to a PC to allow communications between the two.

Measurements for all ARC boxes connected to the MONO OUTPUTs to which the MONO INPUT 1 is assigned

are performed simultaneously.

Refer to the separate M-864D instruction manual for details about ARC measurement such as an installation

example of the measuring microphone.

Step 1. In the Matrix setting screen, assign the MONO INPUT 1 to the MONO OUTPUT connecting the target

ARC box for measurement.

(Example when ARC 1, 2, and 4 are targeted for ARC settings)

Step 2. Click the ARC box targeted for the ARC setting to open the pop-up sub-view.

Step 3. Make the following measurement settings on the Detail Settings

panel: Measurement start and stop frequencies, Sweep time, and

Output level compensation.

Step 4. Install the measuring microphone.

Step 5. Click the Measurement button on the Detail Settings panel to display

the ARC measurement dialog. Then, click the Measurement start

button.

The ARC measurement is started.

The progress status of the measurement is displayed on the screen

as shown in the figure below:

Measurement

Start button

Stop button

Note: To stop before the operation is complete, click the [Stop] button.

Upon measurement completion, the filter parameter is automatically set, displaying the frequency

characteristics in the filter control field.

The measurement target ARC boxes are automatically grouped.

If any of the ARC boxes had been grouped before measurement, this group setting is automatically

canceled at ARC measurement.

3

5

Advertising