5.3.3. operation view

Looking like a mixer console, this view is used to operate the unit’s signal processing functions.

To change signal processing settings, click each of the signal processing function boxes. A pop-up sub-view is

displayed, permitting changes to be entered.

The following operations can be performed for each function box using the menu displayed by right-clicking

the box.

Data can be copied and pasted by dragging and dropping the box.

Copy: Copies the parameters set for the function box selected on the operation view to the clipboard.

Paste: Pastes the data in clipboard to the function box selected on the operation view.

Clear: Initializes the parameters set for the function box selected on the operation view.

Box Write Protect... :

Off: Sets no restriction on write to box.

Low: Restricts the operator from changing the parameters set in the box.

Mid: Restricts the operator from changing all settings in the box.

High: Restricts the administrator from changing the parameters set in the box, and the operator from

changing all settings in the box.

Note: The above operation cannot be performed on the Level Meter box.