Toa M-864D Ver.2.2.0 User Manual

Page 86

Advertising
background image

86

Note

To output a contact for control by the ZM Remote Controller, perform the following operations on the ZM

Remote Controller Settings screen (shown on

p. 87

):

Step 1. Allocate “Remote Switched Out” to the ZM Remote Controller’s “Function” button.

Step 2. Set the contact output terminal number.

[fader tally]

Outputs a Make or Break contact depending on whether the FRONT fader’s gain value exceeds (ON) the

threshold level or not (OFF). The threshold level corresponds to the fader scale “1” (approximately –60 dB).

Terminal control differs depending on the “Control” column setting.

Make: The terminal is closed when in ON status, and is opened when in OFF status.

Pulse: A shorting pulse is generated between the corresponding terminal and the C terminal when the

status changes from ON to OFF.

tip

When no function is allocated to the terminal, select “Break” with the corresponding “Function” column button.

[remote Switched out]

Outputs a Make or Break contact by ON/OFF operation control from the ZM Remote Controller or other

externally connected device.

Both momentary type and latch type are available for the terminal control method. Select either type in the

“Control” Column.

Below is the operation diagram for each type of control method.

ON/OFF operation of

ZM Remote Controller’s

function button

• Momentary type

• Latch type

ON

OFF

OFF

ON

OFF

ON

ON

ON

ON

OFF

OFF

OFF

Contact output state

Make

Beak

Beak

Make

Over 100 ms

Over 100 ms

ON/OFF operation of

ZM Remote Controller’s

function button

Contact output state

Make

Beak

Beak

Make