Specifications, Software specification – Toa M-864D Ver.2.2.0 User Manual

Page 123

Advertising
background image

123

14. SPeCIfICatIoNS

14.1. Software Specification

14.1.1. Preset Memory

16 memories

14.2. Setting Items, Setting ranges, and Default Settings

14.2.1. Unit data

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

Unit Name

20 alphanumeric

characters

IP Address

IPv4

192.168.14.1

Subnet Mask

IPv4

255.255.255.0

Default Gateway

IPv4

0.0.0.0

External Control port

number

3000 to 49151

3000

+1: Level meter

14.2.2. Channel data

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

Unit Name

20 alphanumeric

characters

Example:

Mono In: 1, Stereo

In: 1, Mono Out: 1,

Rec out: L

14.2.3. Signal processing box

[Gain settings]

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

Phantom Power

ON, OFF

OFF

PAD

PAD OFF, PAD ON

PAD ON

LCF ON/OFF

ON, OFF

ON

LCF Cutoff Frequency 20 to 20 k (Hz),

1/24 octave steps

100

LCF Slope

12 dB/oct (fixed)

Gain Volume

PAD OFF:

+15 to +60 (dB), 1 dB

steps

PAD ON:

0 to +18 (dB), 1 dB

steps

PAD OFF: +15 (dB)

PAD ON: 0 (dB)

Advertising