5.3.2. flow view

Displays the unit’s signal processing image by means of a signal flow consisting of Function and Level Meter

boxes, which indicate the unit’s signal processing operation, and a straight line connecting the input and output.

Signal input is at the left of the centrally located signal flow matrix box, and signal output at the right.

To change signal processing settings, click each of the signal processing function boxes. A pop-up sub-view is

displayed, permitting changes to be entered.

The selected function box is highlighted with an orange frame (except for the Level Meter box, which is shown

with a blue frame).

The following operations can be performed for each function box using the menu displayed by right-clicking

the box.

Data can be copied and pasted by dragging and dropping the box.

Copy: Copies the parameters set for the function box selected on the flow view to the clipboard.

Paste: Pastes the data in clipboard to the function box selected on the flow view.

Clear: Initializes the parameters set for the function box selected on the flow view.

Box Write Protect... :

Off: Sets no restriction on write to box.

Low: Restricts the operator from changing the parameters set in the box.

Mid: Restricts the operator from changing all settings in the box.

High: Restricts the administrator from changing the parameters set in the box, and the operator from

changing all settings in the box.

Note: The above operation cannot be performed on the Level Meter box.