Toa M-864D Ver.2.2.0 User Manual

Page 64

Advertising
background image

64

7. oN/off Button

Sets each filter point to ON or OFF.

ON: Filter is enabled (orange display).

OFF: Filter is disabled (blue display).

The filter is bypassed if set to OFF.

8. Lock Button

Used to enable or disable the locking of

frequencies or gains when dragging filter points.

Clicking “Freq. Unlock” at left changes the

indication, locking the frequency.

If the frequency is locked, it becomes

unchangeable even if the filter point is dragged

left and right.

Clicking the same button again restores the

previous display and releases the lock. Clicking

“Gain Unlock” at right changes the indication,

locking the gain.

If the gain is locked, it becomes unchangeable

even if the filter point is dragged up and down

Clicking the same button again restores the

previous display and releases the lock.

Both the frequency and gain can be locked.

Note

Frequencies and gains can only be locked for

the filter point operation. The frequency and gain

controls can be used to change settings even

while in locked mode.

9. resolution Button

Used to set the resolution for frequency and gain

settings.

If “Freq. : Low” at left is clicked, the indication

changes and the frequency settings resolution is

set to “High.”

Clicking the same button again restores the

previous display and sets the frequency settings

resolution to “Low.” The frequency settings

resolution is as follows:

Low: 1/24 octave

High: 3-digit significant figure

If “Gain: Low” at right is clicked, the indication

changes and the gain settings resolution is set to

“High.”

Clicking the same button again restores the

previous display and sets the for gain settings

resolution to “Low.” The gain settings resolution

is as follows:

Low: 0.5 dB

High: 0.1 dB

10. Q Indicator Button

Used to switch the Q display method of each filter

point.

The following 3 different display methods are

available:

(1) Numerical indication

Q values are indicated by a numerical figure.

(2) Oct/band fractional indication

The value of the octave bandwidth

corresponding to the Q value is indicated by a

fractional figure.

(3) Oct/band numerical indication

The value of the octave bandwidth

corresponding to the Q value is indicated by a

numerical figure.

Example: When the Q value is 4.318

Numerical indication: 0.333

Oct/band fractional indication:

1/3 oct/band

Oct/band numerical indication:

4.318 oct/band

11. Grouping Button

Clicking this button opens the dialog for selecting

the grouping number.

Advertising