[feedback suppressor (fBS) settings]

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

Dynamic Mode

ON/OFF

ON, OFF

OFF

Filter Guard ON/OFF

ON, OFF

OFF

Gain

–15 to 0 (dB)

0.1 dB steps

0

Automatically set

in Dynamic mode

Center Frequency

20 to 20 k (Hz),

1/24 octave steps

1 k

Automatically set

in Dynamic mode

Q

0.267 to 69.249

(96 points)

4.318

Automatically set

in Dynamic mode

Filter ON/OFF

ON, OFF

OFF

Automatically set

in Dynamic mode

[Graph indication range of fBS and arC]

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

Graph Indication

Range

(Frequency: Min.)

20 to 19.9 k (Hz)

20

Max. value is

always kept

greater than min.

value.

Graph Indication

Range

(Frequency: Max.)

21 to 20.0 k (Hz)

20.0 k

Graph Indication

Range

(Amplitude: Top)

–119 to +120

6

Top value is

always kept

greater than

bottom value.

Graph Indication

Range

(Amplitude: Bottom)

–120 to +119

–24

Graph Indication

Range

(Amplitude: Step)

1 to 20 (dB),

1 dB steps

3

[aUto MUte settings]

Setting Item

Setting Range

Default Setting

Remarks

Online Setting Storable in

Preset Memory

AUTO MUTE ON/OFF ON, OFF

OFF

Start Threshold Level –69 to +24 (dB),

1 dB steps

–40

End Threshold Level

12 (dB) below Start

Threshold Level

(fixed)

Matrix Crosspoint

Attenuation

–3 to –60 (dB),

3 dB steps

–30

Hold Time

1 to 10 (sec),

1 sec steps

2

Fade-out Time

0.65 (sec) at

attenuation of –30 dB

(fixed slope)

Fade-in Time

1.30 (sec) at

attenuation of –30 dB

(fixed slope)

Advertising