9.3. Connection Settings

Perform settings needed to communicate with the units in this section.

Network settings can be made.

Step 1. Select [Network Connection Setting] from the menu.

Network settings of the units found on the network are displayed.

The table below shows the factory preset settings for each unit.

IP address

192.168.14.1

Subnet mask

255.255.255.0

Default gateway 0.0.0.0

4

5

2

6

3

If no unit was detected:

Install the undetected unit within the reach of broadcast packet.

Communications may be interrupted when the PC is firewall-protected.

If a unit’s IP address is duplicated or inappropriate network setting has been performed, such device is displayed

in the Unconnectable units list.

• To change the unit’s IP address setting, advance to Step 2.

• When transmitting the settings data changed in Step 2 to the unit, advance to Step 3.

• When changing the PC’s network settings, change them from the Windows Control Panel. PC network setting

cannot be changed using the M-864D PC software.

• When connecting to the unit via a router, network settings are not displayed on this screen. The unit network

settings cannot be changed. Connect such unit to a LAN and perform the network settings in advance.

• If a unit needs to be connected via a router, advance to Step 4 to add it.

• If the unit that should not be communicated with is displayed in the list, advance to Step 5 to delete it from the

list.

• Advance to Step 6 when all the units to be connected are displayed in “Connectable units” list.

• When the PC has two or more IP addresses, select the unit and IP address to be communicated with from

the PC’s IP address.