4.3 Rate Limiter

61

4.3 Rate Limiter

To ensure reliable data exchange during heavy traffic, the device can limit the
traffic.

Entering a limit rate for each port specifies the amount of traffic the device is
permitted to transmit and receive.

If the data load transmitted at this port exceeds the maximum load entered,
the device will discard the excess data at this port.

A global setting enables/disables the rate limiter function at all ports.

4.3.1 Rate Limiter settings

X

"Ingress Limiter (kbit/s)" allows you to enable or disable the input limiting
function for all ports.

X

"Egress Limiter (Pkt/s)" allows you to enable or disable the broadcast out-
put limiter function at all ports.

X

"Egress Limiter (kbit/s)" allows you to enable or disable the output limiter
function for all packet types at all ports.

Setting options per port:

X

"Ingress Packet Types" allows you to select the packet type for which the
limit is to apply:

X

All, limits the total inbound data volume at this port.

X

BC, limits the broadcast packets received at this port.

X

BC + MC, limits broadcast packets and Multicast packets received at

this port.

X

BC + MC + uUC, limits broadcast packets, Multicast packets, and un-

known Unicast packets received at this port.

X

Ingress Limiter Rate for the inbound packet type selected: