PENGO TruLink Manual

8” DISPLAY LAYOUT AND FUNCTIONALITY

8” Touch Screen Display
This is the main operating screen. On this screen the operator can view time, date, memory availability, pile number,
depth, torque and angle of pile. When making selections on the touch screen only use your fi nger or the provided soft
tipped stylus. Using hard or pointed objects will cause damage to the display.

Main Screen Functions:
A)
Time:

Displays current time.

B) Date:

Displays current date.

C) Memory:

Indicates internal memory capacity.

D) Pile No:

User input, pile identifi cation for pile being installed.

E) Record Bar: Indicates when data is being recorded.
F) Angle:

Indicates pile angle during installation.

G) Depth:

User input, tracks depth of pile being installed.

H) Pile Locater: Dot is a visual reference of center of Pile being installed.
I) Inclinometer: Dial indicator (Bullseye) visual reference to show pile center.
J) Torque:

Torque selection, touch center to access menu and set the torque value on the dial.

K) Torque Dial: Dial indicator, visual reference displays real time torque.
L) Torque Bar: Numeric indicator, displays real time torque value numerically.
M) Op Torque: Optimum torque indicator. Touch bar to preset optimum torque range.
N) Menu Bar:

Menu bar is used to access main menu, control recording and access the depth interface (Joint).

O) Smart Pin: “SP” Icon when selected will bring up the Pin information such as serial number and hour meter.

J

G

F

A

B

C

D

E

H

I

K

L

M

N

O

TRULINK SYSTEM OPERATION

NOTE: Use the on/off switch located on the Display
Power Harness to control power going to the
display. Do not disconnect the power supply from
the power source. This can result in corruption of
data stored in the Display.

ON / OFF

Switch