Pengo TruLink User Manual

Page 42

Advertising
background image

42

PENGO TruLink Manual

OPERATING PROCEDURES (8” DISPLAY)

USING THE DATA LOGGER:

Select the “Menu” button to access the
main menu screen.

1

Select “Data Logger” from the menu. A
new screen will appear.

2

On the Data Logger screen you will set
the data record interval in increments of
seconds (1 to 60 seconds). Touch the

box to the right of Record Interval. A screen
key pad will appear, enter the number for the
amount of seconds you want to record a torque
measurement. Select Enter when complete.

3

1

2

3

Depth based will require a Range
Finder (sold separately). Use the
blue directional buttons located
at the bottom of the display to set
each entry. When fi nished press
the Menu / Back button.

To set-up the torque value in which the
data logger will start recording touch
the box to the right of Start Logging

Torque. A screen key pad will appear. Enter the
torque value in increments of 1,000 ft/lbs (1,000
to 50,000 ft/lbs).

This features allows operators with a large torque
band to only record data closer to the max torque
requirement. Example max torque is 50,000 ft/
lbs and the operator only wants to start recording
data when the pile reaches 25,000 ft/lbs. The
operator would set the Start Logging Torque at
25,000 ft/lbs. At this setting the system will only
record data at 25,000 and greater. Below 25,000
the system will not record.

4

4

The Mode section does not require any
input. Mode should always be set at
Time Based. Depth based can only be

used with a range fi nder which is sold separately.

5

Advertising