Component identification (8” display option) – Pengo TruLink User Manual

Page 9

Advertising
background image

PENGO TruLink Manual 9

COMPONENT IDENTIFICATION (8” DISPLAY OPTION)

Pengo continually looks for new ways to improve its products. Therefore, Pengo reserves the right to make changes to our
products and specifi cations without notice.

Parts list shown on this page are for the 8” Display option only.

1) 8.4” Touch Screen Display

CAN-based display module with a 8.4” TFT LCD touch
screen. Windows CE operating platform. Input power
supply range from 9 V to 32 V. Operating temperature
range of -20 C to +70 C. IP67 (ingress protection) allows
for outdoor use if required. USB port for data export.

2) TruLink Pin - Classes 1, 2, 3 and 4

Pin contains CPU, inclinometer and strain gages.
Class 1: 45mm diameter pin. (20,000 ft/lbs torque)
Class 2: 75mm diameter pin. (70,000 ft/lbs torque)
Class 3: 100mm diameter pin. (150,000 ft/lbs torque)
Class 4: 114mm diameter pin. (300,000 ft/lbs torque)

3) TruLink End Cap Kit

End Cap Kit is comprised of the end cap, fastening bolt
and installation rod. Used on classes 1 and 2 only.

4) Display Power Harness (8.4” Display)

Wire harness provides power to the display via auxiliary
power coupler. Aux power coupler plugs into the auxiliary
(cigarette lighter) port. Wire harness also connects to
the main cable which links the TruLink pin to the display.

5) Cable Main (lengths are class specifi c)

Wire harness provides power to the display and CAN
logger via a auxiliary power coupler. Aux power coupler
plugs into the auxiliary (cigarette lighter) port. Wire
harness also connects the display and CAN logger to the
electrical cable running to the Anchor Drive wire harness.
Lengths: Class 1: 15’ / Class 2: 25’ / Class 3 & 4: 65’.

6) Battery Back-Up Cable

Kit (harness and back-up box) provides power to the
Display. A Battery Back-Up Box is included with the cable
assembly. The Battery Back-Up Box is used to turn the
display on and off by use of the switch located on the
Battery Back-Up Box.

7) Cable Extension 15’ (Classes 1 & 2)

Cable is used to extend main cable in applications

8) 8.4” Display Mount

Mount is used to position the touch screen display within
the operators cab. Mount can be used with suction cups
(provided) or hard mounted using hardware (not provided).

9) Cable Jib (Classes 3 & 4)

15’ cable used to connect the Pin to the Junction Box.

10) Junction Box

Junction Box used on Class 3 & 4 systems. Junction Box
is located near the end of the excavator boom near the pin.

Allows for quick disconnect when Drive is not in use.

11) Display Protective / Storage Case

Waterproof and impact resistant protective case. Used to
store the TruLink display when not in use.

12) Anti-Rotation Block Kit

Anti-Rotation block is used to position the TruLink pin in the
correct orientation plane. Kit is provided with several types
of hardware to outfi t all Pengo Revolution Series Anchor
Drives.

13) USB Flash Drive

2 GB fl ash drive provided for data export from TruLink

14) Stylus

Silicone tipped stylus, used as a section tool for the touch
screen display.

Advertising