F-4000 Series Ultrasonic Flow Meter Manual 05/15 - 0707-13 / 18838

Page 26

CAUTION

This product must be connected to earth ground for proper operation. Failure to do so may result in

erratic operation.

!

3.6 ELECTRICAL INSTALLATION

All user supplied conduit fittings, junction boxes, etc. must be installed in compliance with
federal, state and local building codes.

3.6.1 Input Power Options

The F-4000 can be ordered with two different input voltage options. This is not user
selectable in the field. The input power options are:

11.5 - 28.5 VDC, 10 Watts maximum

90 - 240 VAC 50/60 Hz, 15 VA maximum

WARNING

Conduit openings in the F-4000 enclosure must be closed with UL listed fittings applicable to NEMA

4 enclosures.

!

WARNING

The protective earth connection must be made as shown in Section 3.6.2. Failure to do so will result

in an increased risk of injury.

!

WARNING

All mains voltage connections must be made through the pre-drilled conduit/strain relief opening

located at the bottom of the enclosure. Failure to do so will result in an increased risk of injury.

!