1.4 STANDARD FEATURES AND SPECIFICATIONS

• Wall-mounted NEMA 4 steel enclosure with 2-line alphanumeric user interface/display
• One externally powered electrically isolated 4-20 mA analog output for flow rate
• One scalable electrically isolated open collector pulse output for totalizing flow
• One programmable form C relay to indicate flow direction or alarm.

GENERAL SPECIFICATIONS

ACCURACY

± 1.0% of reading from 1 to 40 ft/sec

± 0.01 ft/s for velocities below 1 ft/sec

OVERALL FLOW RANGE

0.1 to 40 ft/sec

SENSING METHOD

Clamp-on ultrasonic, differential transit time

method in direct or reflect mode

PIPE SIZE RANGE

½” through 48” nominal diameter

PROGRAMMING

Factory programmed for specific application

MEMORY

Non-volatile memory retains all program

parameters and totalized values in the event of

power loss.

DISPLAY

Alphanumeric 2-line, 16-characters per line

multifunction LCD display

(Character

height,

0.2”)

Displays total flow, flow rate, speed of sound,

% gain, % aeration, signal strength, flow

direction & alarm conditions

Rate display range: 0 - 9,999,999

Totalizer display range: 0 – 99,999,999

Totalizers will roll over to zero when maximum

count is exceeded.

OUTPUT SIGNALS PROVIDED

Analog output: Electrically isolated 4-20 mA

(Externally powered 10 – 30 VDC)

Scalable pulse output: Optically isolated open

collector (Contact rating: 30 VDC, 10 mA

maximum, pulse duration: 50 ms)

Relay output for flow direction or alarm:

Programmable form C relay (Contact rating: 30

VDC, 250 mA maximum)

FLUID TEMPERATURE RANGE

Standard: -40° F to 250° F
Optional: High Temperature -40° F to 446° F

AMBIENT OPERATING TEMPERATURE RANGE

14° F to 122° F

STORAGE TEMPERATURE RANGE

-4˚ F to 140˚ F

MECHANICAL

MATERIALS OF CONSTRUCTION

Electronics enclosure: Wall-mount, powder coat

painted steel enclosure with stainless steel

hardware

Transducer mounting hardware: Anodized

aluminum and stainless steel

Transducers: Anodized aluminum and plastic

ENCLOSURE RATINGS

NEMA 4, weathertight

ELECTRICAL

This equipment is intended for INSTALLATION

CATEGORY (OVERVOLTAGE CATEGORY) II

applications. Installations must comply with all local,

state and federal building codes.

INPUT POWER – Factory selectable

11.5 to 28.5 VDC, 10 Watts maximum

(Internal: 5x20mm, 250V/2.0A fuse)

90-240 VAC 50/60 Hz, 15 VA maximum

(Internal: 5x20mm, 250V/0.5A fuse)

OVERCURRENT PROTECTIVE DEVICE RATINGS:

Supply mains overcurrent protective devices with

the

following

ratings:

120 VAC 50/60 Hz – 15 A

230 VAC 50 Hz – 6 A

ELECTRICAL CONNECTIONS

Enclosed terminal connections, cable access through

four standard ¾” conduit openings

Transducer signals: (2) F-connectors supplied with

quick-disconnect

adapters

Input power: 3 terminal removable connectors

(12 – 22 AWG)

Signal inputs/outputs: PCB mount terminal blocks

(14 – 26 AWG)

WIRING

Transducer signals: Use Belden 9269 coaxial cable or

equivalent (93Ω nominal impedance)

24 VDC input power: Use PVC jacketed copper cable

with a wire gauge suitable for the length of run and

required maximum current carrying capacity.

Provide a separate protective earth wire.

120/230 VAC input power: Use a 3-wire service

with one wire a protective earth ground.

Signal inputs/outputs: Use PVC jacketed copper

shielded cable with a wire gauge suitable for the

length of run and required maximum current

carrying

capacity.