* Protect from prolonged UV exposure.

Pump specifications

Control range (turndown ratio)

0.1-265rpm (2650:1)

Supply voltage/frequency

Filtered 100-120V/200-240V 50/60Hz 1ph

Maximum voltage fluctuation

±10% of nominal voltage. A well

regulated electrical mains supply is

required along with cable connections

conforming to the best practice of noise

immunity

Installation category
(overvoltage category)

II

Power consumption

250VA

Full load current

<1.1A at 230V; <2.2A at 115V

Eprom version

Accessible through pump software

Enclosure rating - 620UN, 620SN

IP66 to BS EN 60529; Equivalent to

NEMA 4X to NEMA 250* (indoor use).

Suitable for heavy industrial, process

and filthy environments. The drive uses

a Gore membrane vent to equalise the

pressure inside the enclosure and to

prevent ingress of water and corrosive

vapours.

Enclosure rating - 620U, 620S

IP31 to BS EN 60529. Equivalent to

NEMA 2, suitable for indoor use.

Protected against dripping water and

falling dirt. May be wiped with a damp

cloth, but should not be immersed.

Pumphead options

620R, 620RE, 620RE4

Operating temperature range

5C to 40C, 41F to 104F

Storage temperature range

-25C to 65C, -13F to 149F

Maximum altitude

2,000m, 6,560ft

Humidity (non-condensing)
(620U, 620S)

80% up to 31C, 88F, decreasing

linearly to 50% at 40C, 104F

Humidity (condensing)
(620UN, 620SN)

10% - 100% RH

Weight

See table on previous page

Noise

<70dB(A) at 1m

Advertising