10 supply voltages – Watson-Marlow 620U User Manual

Page 75

Advertising
background image

Watson-Marlow 620UN, 620U, 620SN, 620S User Manual

75

21.10 Supply voltages

In the table below, "Max load" is the maximum total load on each supply irrespec-
tive of the number of connections.

Note: All DC supplies are stabilised except the +22.5V.

DC
Voltage

Max
load

Lower

D

Upper

D

Typical use

+5V

10mA

9, 19, 23

18, 19

Voltage supply for inputs using
remote switch.
Possible voltage supply for outputs if
only 5V is required.
Pin 9 is specifically used for
footswitch / handswitch operation

+12V

10mA

25

21

Possible voltage supply for inputs
using remote switch.
Possible voltage supply for outputs.
Voltage supply for Watson-Marlow
Tube Monitor leak detector.
Part voltage supply (-12V also need-
ed) for the Watson-Marlow proximity
switch

-12V

10mA

24

-

Part voltage supply (+12V also need-
ed) for the Watson-Marlow proximity
switch

+22.5V

-

20

Voltage supply for the 620N wash-
down module. Do not use

+10V

21

-

Reference voltage for remote poten-
tiometer speed control. Do not use
as a general supply voltage

Advertising