Slave – ATL Telecom OM100 User Manual

Page 10

Advertising
background image

ATL USER GUIDE

OM100 Optical Multiplexer

17

CONNECTING THE OM100 1+1 SF SM OPTICAL FIBRES

The Optical fibres must be connected as in Fig 3.2.4 :

Main Link: Optical Line 1 on the Master unit must be connected to Optical Line 2 on the
Slave unit.

Backup Link: Optical Line 2 on the Master unit must be connected to Optical Line 1 on the
Slave unit.

FIGURE 3.2.4

Slave

Optical 1

Optical 2

st

Optical 1

Optical 2

Master

Slave

3

16

ATL USER GUIDE
OM100 Optical Multiplexer

3.5.2.2

Single fibre, single-mode

FIGURE 3.2.2

INFORMATION RELATING TO OM100 SINGLE-FIBRE SINGLE-MODE SLAVE (1/352/3XX)

Emitted wavelength = 1310nm
Maximum output laser radiation < 5mW
Laser classification = Class 1 to EN 60825:1994

INFORMATION RELATING TO OM100 SINGLE-FIBRE SINGLE-MODE MASTER (1/352/4XX)

Emitted wavelength = 1550nm
Maximum output laser radiation < 7mW
Laser classification = Class 1 to EN 60825:1994

3.5.2.3

1+1 single fibre, single-mode

FIGURE 3.2.3

INFORMATION RELATING TO OM100 1+1 SINGLE-FIBRE SINGLE-MODE (1/352/5XX)

Emitted wavelength = 1310nm & 1550nm
Maximum output laser radiation <5mW @ 1310nm & <7mw @ 1550nm
Laser classification = Class 1 to EN 60825:1994

12
OPTICAL LINE

DC 1

DC 2

CH 1

CH 2

CH 3

CH 4

BOOT

- 48V /100mA

12
OPTICAL LINE

DC 1

DC 2

CH 1

CH 2

CH 3

BOOT

- 48V /100mA

Advertising