ATL Telecom OM100 User Manual

Page 40

Advertising
background image

ATL USER GUIDE

OM100 Optical Multiplexer

77

Optical alarms

Traffic in fail (LOS)
Laser fault
BER>1x10-3
BER>1x10-6

Protection Switching Interface

Integrated in unit (optional)

Management

Local terminal port, remote modem connection,
limited push button configuration

Loopbacks

User port local & remote

Loopback control

Via Management stations

Push button configuration

Size

Customer unit – 169 x 49 x 206mm (W x H x D)

Power Supply

Input Voltage

Current

Power Consumption

Customer unit

-48V dc

100mA

4.8W nominal

Operating temperature

-10° ~ 50° C

Operating humidity

Maximum 95% non condensing

76

ATL USER GUIDE
OM100 Optical Multiplexer

User port specifications

Data rate

2.048Mbps

Use

G.703, E1, primary rate ISDN

Connections RJ-45

Termination impedance

120

Intrinsic jitter

0.09 UI peak to peak (20Hz – 100KHz)

Jitter transfer

30dB at 100Hz (1.5 UI in)
40dB at 1KHz (1.5 UI in)
< 60dB at 10KHz (0.2 UI in)

Maximum tolerable input Jitter

>20 UI in at 100Hz
12 UI at 1KHz
2.5 UI at 10KHz

Additional delay

> 50 µS

Maximum traffic clock offset

> ±150ppm

Traffic Alarms

Traffic in fail (LOS)
AIS detected
BER>1x10-3
BER>1x10-6

Optical port specifications

Optical system
type

Atten. max

Atten. min

P

TX

P

RX

Wavelength

Con. No.

Con. type

Fibre type

Class

Multi-mode
dual fibre

18dB

0dB

-9dBm

-27dBm

850nm

2

ST

G.651

1

Single-mode
single fibre

25dB

0dB

-7dBm

-32dBm

1310/1550nm

1

FC-PC, ST or SC

G.652

1

1+1 single-mode
(single fibres)

25dB

0dB

-7dBm

-32dBm

1310/1550nm

2

FC-PC, ST or SC

G.652

1

8