The master unit is in charge of managing the optical link, it is also the 'master' from a
network management point of view. It contains the database of configuration information for
itself and the slave unit. The alarm and performance monitoring history is saved at the master.

When the management terminal is connected to the master it can read all of the information
from the local and remote units, whereas when the management terminal is connected to the
slave, only the local information is obtainable.

* Note: Master/Slave settings are fixed for these units and cannot be altered, and a message
indicating this will be displayed for single fibre units.

It is possible to set Master/Slave by using the front panel buttons if a terminal is unavailable,
see Appendix B.

Unit Default

Settings

OM100 DF DM

Slave

OM100 DF SM

Slave

OM100 SF SM Master

Master*

OM100 SF SM Slave

Slave*

OM100 1+1 SF SM

Slave

ATL USER GUIDE

OM100 Optical Multiplexer

53

52

ATL USER GUIDE
OM100 Optical Multiplexer

7.2.2

User port configuration

Description

Turns this user port ON, or OFF.

When OFF all traffic on this port is blocked and is replaced with AIS.

When off (default) port timing is independant of other ports.

When on the port operates in SDH mode - refer to section 3.6.2.

Field

Enable

Lock Clock to

Reference

OM100 Mon 01 Nov 2002 00:34:32

Config > User Ports

Urgent Alarm:On Non-Urgent Alarm:Off

Subsystem: LT

Lock Clock

Enable to Reference

Port 1 [X]

Port 2 [X] [ ]

Port 3 [X] [ ]

Port 4 [X] [ ]

Press Return to Accept or Escape to Cancel

F1 Help F3 Previous Menu F4 Main Menu

Configuration

Master / Slave

Master / slave configuration.

User Port

Configure each E1 port – enable.

Protection Switching

Configures the protection 1+1 switching.

System

Set date, time and menu timeout.

Subsystem Names

Enter name, description and location of this unit.

Monitoring Mode

Configures monitoring mode.

Software

Allows the downloading of software to the unit

and allows reset to factory default.

Serial Communications

Local terminal set-up – baud rate, parity, handshake.

Reboot

This option allows you to reboot the unit that you

are using, as well as its remote partner.

Front Panel

Allows configuration of Front Panel controls.

7