The single colour LED indicators are interpreted as follows:

Master (Green)

When lit, this LED indicates that the unit has been configured to operate as a 'master'. The
default setting is for the unit to be a 'slave', in which case the LED will be turned off.

Test (Red)

This will be illuminated whenever a loop test is active in the system. i.e. The LED will
illuminate no matter which end of the link the test is applied.

ATL USER GUIDE

OM100 Optical Multiplexer

31

30

ATL USER GUIDE
OM100 Optical Multiplexer

3.7.1.4

Setting Loops

The following test loops may be set using the front panel buttons.

o Local Loop

o Loop back

o Remote Loop

Note. These buttons may be disabled from the 'Configuration > Front Panel' menu.

3.7.2

Indicators

There are seven tri-colour LEDs that provide status information. These are interpreted as
follows:

*The status LED flashes Green when the unit is in programming mode.

+only active on OM100 1+1 SF SM units.

LED

Red. Urgent

Amber.

Non-Urgent

Green

Off

Status*

System Alarm

System Alarm

OK

Power OFF

Optical 1

Optical Alarm

e.g. LOS, High BER

Optical Alarm

e.g. Low BER

OK N/A

Optical 2

+

Optical Alarm

e.g. LOS, High BER

Optical Alarm

e.g. Low BER

OK N/A

Ch.1. .4

User Port Alarm

e.g. LOS, AIS, High BER

User Port Alarm

e.g. Low BER

OK

No input signal

at user port

Local Loop

Loop back

Remote Loop

Local Unit

Remote Unit