6.3

CONFIGURATION SCREENS

6.3.1

Entering data

6.3.2

Moving between check boxes

Select check boxes and radio buttons in the same way.

Pressing either the right cursor key, or the <TAB> key cycles through the check boxes. Use the
left cursor, or <BACK TAB> key to cycle backwards.

6.3.3

Turning functions on and off

Find the appropriate check box associated with the function you want to change. Move the
cursor to that check box. Then press the space bar to change the box. Repeat for all other
required changes. Press the <return> key to accept the configuration.

Note: The configuration is not accepted until the <return> key is pressed. In this way mistakes
can be corrected before the data is entered. Beware though, if you exit the screen before
pressing <return> the changes will be cancelled. Pressing the <return> key makes the changes
and exits the screen, so you may want to make more than one change to the screen before
pressing the <return> key.

OM100 Mon 01 Nov 2002 00:34:32

Config > User Ports

Urgent Alarm:On Non-Urgent Alarm:Off

Subsystem: LT

Lock Clock

Enable to Reference

Port 1 [X]

Port 2 [X] [ ]

Port 3 [X] [ ]

Port 4 [X] [ ]

Press Return to Accept or Escape to Cancel

F1 Help F3 Previous Menu F4 Main Menu

Check boxes turn functions
ON and OFF.

ATL USER GUIDE

OM100 Optical Multiplexer

41

40

ATL USER GUIDE
OM100 Optical Multiplexer

6.2

INFORMATION SCREENS

These screens provide version, alarm and performance information about the system. They are
particularly useful in helping locate problems with any of the ports.

A master unit can view information about itself and about the remotely connected slave unit. A
slave unit can only view it’s local information.

[X] indicates that the
alarm detector is active

Trip counters can be reset

View the remote unit

View next port statistics

OM100 Mon 01 Nov 2002 00:54:49

Performance > User Port

Urgent Alarm:Off Non-Urgent Alarm:On

Subsystem: LT

Port: 1

LOS Detected [ ] BER > 1E-3 [x]

AIS Detected [ ] BER > 1E-6 [ ]

Line Code Violations 0 Trip Counter 0

Available Seconds 100 Trip Counter 100

Unavailable Seconds 0 Trip Counter 0

Severely Errored Seconds 0 Trip Counter 0

Errored Seconds 0 Trip Counter 0

Error Free Seconds 100 Trip Counter 100

Press Escape to Exit

F1 Help F3 Previous Menu F4 Main Menu F5 Previous Channel

F6 Next Channel F7 Previous Subsystem F8 Next Subsystem F9 Reset Trips

F10 Reset System Counters