ATL Telecom OM100 User Manual

Page 26

Advertising
background image

ATL USER GUIDE

OM100 Optical Multiplexer

49

Description

Each alarm is given a unique number.

Refer to Section 7.1.3.2 for description of the various alarms.

The severity level for each alarm is configurable.
Alarms can be filtered in the alarm screen based on severity level.
The non-urgent and urgent alarms are based on this severity level.

5 (highest priority)

Generate the URGENT alarm.

Fault recorded in the fault log.

4

Generate the URGENT alarm.

Fault recorded in the fault log.

3

Generate the Non-URGENT alarm.

Fault recorded in the fault log.

2

Generate the Non-URGENT alarm.

Fault recorded in the fault log.

1

Fault recorded in the fault log.

0 (lowest priority)

Alarm disabled. Not logged or displayed.

Field

Id

Fault description

level

7

48

ATL USER GUIDE
OM100 Optical Multiplexer

7.1.3

Alarm severity level settings

F5 Default

To restore the default alarm severity level to an alarm – use the cursors to highlight the desired
line, then press F5 to restore its default alarm severity level.

OM100 Mon 01 Nov 2002 00:47:28

Alarm > Severity Level Settings

Urgent Alarm:Off Non-Urgent Alarm:On

Id| Fault Description | Level

001|Cold Boot <1>

002|Warm Boot <1>

003|Failed to program (Fault:%n) <1>

004|Power Fail <5>

005|Security - password rejected <1>

006|Test Active <1>

007|H/W - Configuration Memory Fail <5>

008|H/W - FPGA Configuration Fail <5>

009|Optical Port %n - LOS <5>

010|Optical Port %n - Laser Fault <3>

Press Return to Accept or Escape to Cancel

F1 Help F3 Previous Menu F4 Main Menu F5 Default F7 Previous Page

F8 Next Page

Alarm severity can be individually
programmed for every alarm

Levels 4&5 alarms activate the
URGENT alarm

Levels 2&3 alarms activate
the Non-URGENT alarm

Level 1 alarms are only
recorded in the fault log

Id's 11 to 20 are on screen 2.
Press F8 to scroll down.

Alarms

Status

Displays the current alarm status.

History

Review the fault log. View recorded alarm events.

Severity Level Settings

Set fault level. Configure Urgent & Non urgent

alarm sources.