ATL Telecom OM100 User Manual

Page 41

Advertising
background image

ATL USER GUIDE

OM100 Optical Multiplexer

79

9.1

LVD SAFETY STATEMENTS

1. This apparatus must be installed and maintained by SERVICE PERSONNEL.

2. Power Rating Information

DC Input
Voltage Range -36V to -60V.
Current 100mA.

110V AC adaptor (atl part number 5500000038)
Input: 110Vac, 150mA, 50/60Hz
Output: -48VDC 170mA

240V AC adaptor (atl part number 5500000041)
Input: 230Vac, 90mA, 50/60Hz
Output: -48VDC 170mA

The mains plug on the PSU input serves as the disconnect device, therefore a socket outlet
shall be installed near the equipment and shall be made accessible.

3. A protective earth connection must be made to the rear panel earthing stud using a

suitable bonding conductor if any G.703 cable is routed through an external environment,
or reliable earth connection is not provided to the DC input connector.

9.2

SAFETY STATEMENTS

The optical interface is classified as a CLASS 1 LASER PRODUCT.
The mains input connection has a HAZARDOUS VOLTAGE safety status.
The G.703 120

Ω Digital Network Interface Port has a safety status of EARTHED SELV.

The TERM Port has a safety status of UNEARTHED SELV.
The –48Vdc input to the unit is classified as TNV2.

9.3

TELECOMMUNICATION SPECIFICATIONS

The equipment is in conformity with the following Common Technical Regulations and
National Standards:

Common Technical Regulations
CTR12

G.703 2Mbps, 120

Ω, unstructured

CTR13

G.703 2Mbps, 120

Ω, structured

9

S A F E T Y S T A T E M E N T S A N D C O M P L I A N C E N O T E S

78

ATL USER GUIDE
OM100 Optical Multiplexer

Standards

G.651

Characteristics of multi-mode optical fibre cable

G.652

Characteristics of single-mode optical fibre cable

G.703

2.048Mbps electrical parameters

G.704

Frame structure

G.706

Framing algorithms

G.823

Jitter and wander limits

G.826

Error performance

I.431

Primary rate ISDN layer 1

M.3604

Maintenance principals

ETS 300 011

PRI user-network interface

ETS 300 233

Primary rate ISDN access

EN 60825

Optical safety

EN 60950

Safety

ETS 300 019-1-3

Environmental

EN55022

RF emissions limits

EN300386 V1.2.1

EMC requirements for network equipment

EN61000-4-2

ESD protection

EN61000-4-3

Electromagnetic field immunity

EN61000-4-4

Fast burst transients

EN61000-4-5

Surge Immunity

EN61000-4-6

Conducted disturbance immunity

EN61000-4-11

Voltage dips and short interrupts