ATL Telecom OM100 User Manual

Page 27

Advertising
background image

ATL USER GUIDE

OM100 Optical Multiplexer

51

7.2

CONFIGURATION

7.2.1

Master/Slave configuration

In order for a pair of units to operate correctly, one end must be set as a master, the other end
as a slave. Normally the unit connected to the customer will be configured as a slave.

OM100 Mon 01 Nov 2002 00:40:26

Configuration > Master/Slave Operation

Urgent Alarm:On Non-Urgent Alarm:Off

Master (*)

Slave ( )

Saving changes to this screen will cause unit to reboot

Press Return to Accept or Escape to Cancel

F1 Help F3 Previous Menu F4 Main Menu

Configuration

Master / Slave

Master / slave configuration.

User Port

Configure each E1 port – enable.

Protection Switching

Configures the protection 1+1 switching.

System

Set date, time and menu timeout.

Subsystem Names

Enter name, description and location of this unit.

Monitoring Mode

Configures monitoring mode.

Software

Allows the downloading of software to the unit

and allows reset to factory default.

Serial Communications

Local terminal set-up – baud rate, parity, handshake.

Reboot

This option allows you to reboot the unit that you

are using, as well as its remote partner.

Front Panel

Allows configuration of Front Panel controls.

7

50

ATL USER GUIDE
OM100 Optical Multiplexer

7.1.3.2

Alarm sources

*Where n = 1..4 and m = 1..2

Definition

Restart activated by power failure.

Restart activated by the software.

AIS detected on user port (applies to each of the 4 ports).

LOS detected on user port (applies to each of the 4 ports).

High bit error rate on user port (applies to each of the 4 ports).

Low bit error rate on user port (applies to each of the 4 ports).

Failed logon attempt.

Error whilst retrieving stored configuration.

Internal

fault

Internal

fault

Sync loss detected on optical port (applies to each optical port).

High bit error rate on optical port (applies to each optical port)

Low bit error rate on optical port (applies to each optical port)

Fault detected on the optical transmitter (applies to each optical port)

APS has switched to the backup link

Loopback, or test mode active

Fault description

Cold Boot

Warm Boot

User Port n* AIS

User Port n* LOS

User Port n*
BER > 1E3

User Port n
BER > 1E6

Security –
password rejected

H/W – Configuration
Memory Fail

H/W – FPGA
Configuration Fail

Failed to program
(Fault:%n)

Optical Port LOS

Optical Port m*
BER > 1E-3

Optical Port m*
BER > 1E-6

Optical Port m*
Laser Fault

Optical Port –
Backup Link Active

Test active