Chapter 16 Clock Supervisor

4.Operation Modes

■

Disabling the RC-oscillator and the clock supervisors

The initial point of this scenario is that the RC-oscillator and main clock or sub-clock supervisor is enabled.

•

The RC-oscillator can be disabled by setting bit RCE (bit 4 of CSVCR) to ’0’. First disable the main clock and
sub-clock supervisor. Do not disable the RC-oscillator while either the main clock or sub-clock supervisor is
still enabled. Then check that both SM and MM (bit 5 and bit 6 of CSVCR) are still ’0’. Disable the RC-
oscillator by setting RCE to ’0’. If either SM or MM bit is ’1’, RCE must not be set to ’0’.

•

The main clock supervisor is disabled by setting MSVE (bit 3 of CSVCR) to ’0’.

•

The sub-clock supervisor is disabled by setting SSVE (bit 2 of CVSVR) to ’0’.

Figure 4-6 Timing Diagram: Disabling the RC-oscillator and the clock supervisors

PONR

MCLK

SCLK

RC_CLK

OSC_STAB

MSVE

MSEN

SSVE

SSEN

MCLK_STBY

SCLK_STBY

TO_MCLK

TO_SCLK

EXT_RST

EXT_RST_OUT

MCLK_OUT

SCLK_OUT

MCLK_MISSING

SCLK_MISSING

SRST

RCE