3 recovering from stop mode via an interrupt – FUJITSU MB91460 SERIES FR60 User Manual

Page 271

Advertising
background image

255

Chapter 18 Timebase Counter

5.Operation

Watchdog reset when main clock operating

Although no oscillation stabilization wait is required in this case, the specified wait time is generated
automatically.

5.3 Recovering from Stop Mode via an Interrupt

When changing from main PLL operation to stop mode with the main clock oscillation halted
(STCR.OSCD[2:1]=“11”):

The main oscillation circuit generates the selected oscillation stabilization time automatically.

Figure 5-3 Recovering from Stop Mode with the Main Clock Halted to

Main PLL Operation via an Interrupt

(1) Enabled interrupt is generated (end stop mode)

(2) The timebase counter is cleared automatically and then starts counting.

(3) Oscillation stabilization wait time (specified value)
(Set the interval time beforehand to provide an adequate oscillation stabilization wait time.)

(4) Interval time for timebase counter

(5) Main PLL operation

(5)

000h

Using the time-base timer to wait
main PLL lock

Example main PLL
startup

13

2

Time-base
counter count

(1)

Clear the time-base counter.

(CTBR)

Enable main PLL (PLL1EN)

Enable the time base timer
interrupt request. (PLL1EN)

Time base timer interrupt
request (PLL1EN)

(2)

Setting or switching
the main PLL value
(PLL1S[2:0])

Clock switching (CLKS[1:0])

Operation of the divided- by-2 main clock

Operation of the PLL clock

Provide a sufficient oscillation
stabilization wait time.

Time

(8)

(5)

(8)

(5)

(6)

(7)

(9)

(10)

(3)

(4)

(9)

“A5”

“00”

“111”

“10”

“5A”

Advertising