565

Chapter 31 External Bus

5.Operation of the Ordinary bus interface

5.3 Read -> Write Operation

This section shows the operating timing for read -> write.

Operation Timing of Read -> Write

Figure 5-3

"Timing Chart for Read -> Write" shows the operation timing for (TYP3-0=0000

B

, AWR=0048

H

).

Figure 5-3 Timing Chart for Read -> Write

Setting of the W07/W06 bits of the AWR register enables 0-3 idle cycles to be inserted.

Settings in the CS area on the read side are enabled.

This idle cycle is inserted if the next access after a read access is write access or access to another area.

5.4 Write -> Write Operation

This section shows the operation timing for write -> write.

Write -> Write Operation

Figure 5-4

"Timing Chart for the Write -> Write Operation" shows the operation timing for (TYP3-0=0000

B

,

WR=0018

H

).

MCLK

AS

CSn

RD

WRn

D[31:0]

A[31:0]

Read

Write

Idle *