1 single-shot conversion mode – FUJITSU MB91460 SERIES FR60 User Manual
Page 913

897
Chapter 44 A/D Converter
4.Operation of A/D Converter
4.1 Single-shot conversion mode
(1)
Channel selection
(2)
A/D conversion activation (Trigger input: Software trigger/Reload timer/External trigger)
(3)
INT flag clear, BUSY flag set
(4)
Sample hold
(5)
Conversion (Conversion a + Conversion b + Conversion c)
(6)
Conversion end, INT flag set, BUSY flag clear
(7)
Buffers the conversion value. Buffered data storage
(8)
Software-based INT flag clear
Channel
selection
Activation
(trigger)
AN input
Internal level
Conversion
value
Conversion
a
Conversion
b
Conversion
c
Sample
hold
Buffer
(ADT)
Conversion end
(INT)
BUSY
Flag clear
(A/D conversion
activation,
or software)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
Flag clear on A/D conversion activation
Conversion time
Conversion in progress
Finalized
Previous conversion value
New conversion value